[{"command":"settings","settings":{"basePath":"\/","pathPrefix":"hi\/","ajaxPageState":{"theme":"csir","theme_token":"NwScPBRq7UVxY3cMWJ0B-tt9ryDoagW2UNPpo4Y2haY"},"encrypt_submissions":{"baseUrl":"https:\/\/serc.res.in"}},"merge":true},{"command":"insert","method":"replaceWith","selector":"#node-1926","data":"\u003Cdiv id=\u0022node-1926\u0022 class=\u0022node node-expertise-research-developement clearfix\u0022 about=\u0022\/hi\/studies-precast-structural-system-under-seismic-loading\u0022 typeof=\u0022sioc:Item foaf:Document\u0022\u003E\n\n        \u003Ch2\u003E\n      \u003Ca href=\u0022\/hi\/studies-precast-structural-system-under-seismic-loading\u0022\u003EStudies on precast structural system under seismic loading\u003C\/a\u003E\n    \u003C\/h2\u003E\n    \u003Cspan property=\u0022dc:title\u0022 content=\u0022Studies on precast structural system under seismic loading\u0022 class=\u0022rdf-meta element-hidden\u0022\u003E\u003C\/span\u003E\u003Cspan property=\u0022sioc:num_replies\u0022 content=\u00220\u0022 datatype=\u0022xsd:integer\u0022 class=\u0022rdf-meta element-hidden\u0022\u003E\u003C\/span\u003E\n  \n  \u003Cdiv class=\u0022content clearfix\u0022\u003E\n    \u003Cdiv class=\u0022field field-name-body field-type-text-with-summary field-label-hidden\u0022\u003E\u003Cdiv class=\u0022field-items\u0022\u003E\u003Cdiv class=\u0022field-item even\u0022 property=\u0022content:encoded\u0022\u003E\u003Ch3 class=\u0022title_3\u0022\u003EStudies on precast structural system under seismic loading\u003C\/h3\u003E\n\u003Ch3 class=\u0022title_3\u0022\u003EPrecast Structural Systems under Seismic Loading\u003C\/h3\u003E\n\u003Cp\u003EEarthquake resistant building with precast concrete elements needs special attention to joints\u003C\/p\u003E\n\u003Cdiv class=\u0022row_section tog_img_2 tog_img_row clearfix\u0022\u003E\n\u003Cdiv class=\u0022tog_img_col\u0022\u003E\n\u003Cdiv class=\u0022line_hover\u0022\u003E\u003Ca data-fancybox=\u0022res_stu\u0022 href=\u0022\/sites\/default\/files\/amlrnd3a.jpg\u0022\u003E\u003Cimg alt=\u0022Studies on precast structural system under seismic loading\u0022 src=\u0022\/sites\/default\/files\/amlrnd3a.jpg\u0022 title=\u0022Studies on precast structural system under seismic loading\u0022 \/\u003E\u003C\/a\u003E\u003C\/div\u003E\n\u003C\/div\u003E\n\u003Cdiv class=\u0022tog_img_col\u0022\u003E\n\u003Cdiv class=\u0022line_hover\u0022\u003E\u003Ca data-fancybox=\u0022res_stu\u0022 href=\u0022\/sites\/default\/files\/amlrnd3b.png\u0022\u003E\u003Cimg alt=\u0022Studies on precast structural system under seismic loading\u0022 src=\u0022\/sites\/default\/files\/amlrnd3b.png\u0022 title=\u0022Studies on precast structural system under seismic loading\u0022 \/\u003E\u003C\/a\u003E\u003C\/div\u003E\n\u003C\/div\u003E\n\u003C\/div\u003E\n\u003Cul class=\u0022ul-list ul_li_icons cong_icon\u0022 style=\u0022text-align:justify;\u0022\u003E\n\u003Cli\u003EGrid system with light weight infill\u003C\/li\u003E\n\u003Cli\u003EReinforcement detailing ensures large ductility with retention of strength\u003C\/li\u003E\n\u003Cli\u003EReduction in dead weight of structure\u003C\/li\u003E\n\u003Cli\u003EImproper compaction of concrete eliminated\u003C\/li\u003E\n\u003C\/ul\u003E\n\u003Cdiv class=\u0022row_section tog_img_row clearfix\u0022\u003E\n\u003Cdiv class=\u0022tog_img_col1\u0022\u003E\n\u003Cdiv class=\u0022line_hover\u0022\u003E\u003Ca data-fancybox=\u0022res_stu1\u0022 href=\u0022\/sites\/default\/files\/ctools\/amlrnd3c-300x219.jpg\u0022\u003E\u003Cimg alt=\u0022Studies on precast structural system under seismic loading\u0022 src=\u0022\/sites\/default\/files\/ctools\/amlrnd3c-300x219.jpg\u0022 title=\u0022Studies on precast structural system under seismic loading\u0022 \/\u003E\u003C\/a\u003E\u003C\/div\u003E\n\u003C\/div\u003E\n\u003C\/div\u003E\n\u003Cul class=\u0022ul-list ul_li_icons cong_icon\u0022\u003E\n\u003Cli\u003ESize of assemblage : 2590*2300*2640 mm\u003C\/li\u003E\n\u003Cli\u003EInterior joint assembly comprising two floor\u00a0slab\u00a0 units \u0026amp; two wall\u00a0 panel units\u003C\/li\u003E\n\u003Cli\u003EEquivalent moment cyclically applied on\u00a0 wall panel\u003C\/li\u003E\n\u003Cli\u003EJoints withstood service and ultimate load\u003C\/li\u003E\n\u003C\/ul\u003E\n\u003Ch3 class=\u0022title_3\u0022\u003EOutcome of the study\u003C\/h3\u003E\n\u003Cul class=\u0022ul-list ul_li_icons cong_icon\u0022\u003E\n\u003Cli\u003ENovel prefabricated light weight system developed utilises new materials and sustains cyclic loads besides regular loads\u003C\/li\u003E\n\u003C\/ul\u003E\n\u003C\/div\u003E\u003C\/div\u003E\u003C\/div\u003E  \u003C\/div\u003E\n\n      \u003Cdiv class=\u0022link-wrapper\u0022\u003E\n      \u003Cul class=\u0022links inline\u0022\u003E\u003Cli class=\u0022node-readless first\u0022\u003E\u003Ca href=\u0022\/hi\/more\/node\/1926\/teaser\u0022 class=\u0022use-ajax\u0022\u003ERead less\u003C\/a\u003E\u003C\/li\u003E\n\u003Cli class=\u0022translation_en\u0022\u003E\u003Ca href=\u0022\/studies-precast-structural-system-under-seismic-loading\u0022 title=\u0022Studies on precast structural system under seismic loading\u0022 class=\u0022translation-link\u0022 xml:lang=\u0022en\u0022\u003EEnglish\u003C\/a\u003E\u003C\/li\u003E\n\u003Cli class=\u0022translation_ta last\u0022\u003E\u003Ca href=\u0022\/ta\/studies-precast-structural-system-under-seismic-loading\u0022 title=\u0022Studies on precast structural system under seismic loading\u0022 class=\u0022translation-link\u0022 xml:lang=\u0022ta\u0022\u003E\u0ba4\u0bae\u0bbf\u0bb4\u0bcd\u003C\/a\u003E\u003C\/li\u003E\n\u003C\/ul\u003E    \u003C\/div\u003E\n  \n  \n\u003C\/div\u003E","settings":null},{"command":"invoke","selector":"#node-1926","method":"addClass","arguments":["more-load node-teaser"]},{"command":"readmore_ajax","speed":"350"}]