[{"command":"settings","settings":{"basePath":"\/","pathPrefix":"ta\/","ajaxPageState":{"theme":"csir","theme_token":"Mg28S7JBf46B6UGQc-7o_vJ3x_jgsrWCfV5aQmG4xCA"},"encrypt_submissions":{"baseUrl":"https:\/\/serc.res.in"}},"merge":true},{"command":"insert","method":"replaceWith","selector":"#node-2907","data":"\u003Cdiv id=\u0022node-2907\u0022 class=\u0022node node-research-external-projects clearfix\u0022 about=\u0022\/ta\/studies-performance-evaluation-reinforcing-bar-couplers\u0022 typeof=\u0022sioc:Item foaf:Document\u0022\u003E\n\n        \u003Ch2\u003E\n      \u003Ca href=\u0022\/ta\/studies-performance-evaluation-reinforcing-bar-couplers\u0022\u003EStudies on performance evaluation of reinforcing bar couplers\u003C\/a\u003E\n    \u003C\/h2\u003E\n    \u003Cspan property=\u0022dc:title\u0022 content=\u0022Studies on performance evaluation of reinforcing bar couplers\u0022 class=\u0022rdf-meta element-hidden\u0022\u003E\u003C\/span\u003E\u003Cspan property=\u0022sioc:num_replies\u0022 content=\u00220\u0022 datatype=\u0022xsd:integer\u0022 class=\u0022rdf-meta element-hidden\u0022\u003E\u003C\/span\u003E\n  \n  \u003Cdiv class=\u0022content clearfix\u0022\u003E\n    \u003Cdiv class=\u0022field field-name-body field-type-text-with-summary field-label-above\u0022\u003E\u003Cdiv class=\u0022field-label\u0022\u003EAbout:\u0026nbsp;\u003C\/div\u003E\u003Cdiv class=\u0022field-items\u0022\u003E\u003Cdiv class=\u0022field-item even\u0022 property=\u0022content:encoded\u0022\u003E\u003Ch3 class=\u0022title_4\u0022\u003EClient :\u00a0\u003C\/h3\u003E\n\u003Cp\u003EHalfen Moment India Private Limited, Mumbai\u003C\/p\u003E\n\u003Ch3 class=\u0022title_4\u0022\u003EScope of the project:\u003C\/h3\u003E\n\u003Cul class=\u0022ul-list ul_li_icons cong_icon\u0022 style=\u0022text-align:justify;\u0022\u003E\n\u003Cli\u003EStatic tensile tests on parent bar.\u003C\/li\u003E\n\u003Cli\u003EStatic tensile tests on coupled bars of diameters\u003C\/li\u003E\n\u003Cli\u003ETensile cyclic load testing of coupled bars for 100 cycles in the stress range of 0.05fy to 0.9fy for coupled bars\u003C\/li\u003E\n\u003Cli\u003ELow cycle fatigue tests on coupled bars for 10000 cycles under fully reversed stress range of \u00b1173 MPa.\u003C\/li\u003E\n\u003Cli\u003ESlip test on coupled bars\u003C\/li\u003E\n\u003C\/ul\u003E\n\u003C\/div\u003E\u003C\/div\u003E\u003C\/div\u003E\u003Cdiv class=\u0022field field-name-field-project-images field-type-image field-label-above\u0022\u003E\u003Cdiv class=\u0022field-label\u0022\u003EProject Images:\u0026nbsp;\u003C\/div\u003E\u003Cdiv class=\u0022field-items\u0022\u003E\u003Cdiv class=\u0022field-item even\u0022\u003E\u003Cimg typeof=\u0022foaf:Image\u0022 src=\u0022https:\/\/serc.res.in\/sites\/default\/files\/halfen1.jpg\u0022 width=\u0022641\u0022 height=\u0022454\u0022 alt=\u0022Testing of parent bar and coupler bar\u0022 title=\u0022Testing of parent bar and coupler bar\u0022 \/\u003E\u003C\/div\u003E\u003Cdiv class=\u0022field-item odd\u0022\u003E\u003Cimg typeof=\u0022foaf:Image\u0022 src=\u0022https:\/\/serc.res.in\/sites\/default\/files\/halfen2.jpg\u0022 width=\u0022570\u0022 height=\u0022449\u0022 alt=\u0022Tensile cyclic load testing of coupled bars for 100 cycles in the stress range of 0.05fy to 0.9fy for coupled bars\u0022 title=\u0022Tensile cyclic load testing of coupled bars for 100 cycles in the stress range of 0.05fy to 0.9fy for coupled bars\u0022 \/\u003E\u003C\/div\u003E\u003Cdiv class=\u0022field-item even\u0022\u003E\u003Cimg typeof=\u0022foaf:Image\u0022 src=\u0022https:\/\/serc.res.in\/sites\/default\/files\/halfen3.jpg\u0022 width=\u0022710\u0022 height=\u0022236\u0022 alt=\u0022Failure pattern\u0022 title=\u0022Failure pattern\u0022 \/\u003E\u003C\/div\u003E\u003Cdiv class=\u0022field-item odd\u0022\u003E\u003Cimg typeof=\u0022foaf:Image\u0022 src=\u0022https:\/\/serc.res.in\/sites\/default\/files\/halfen4.jpg\u0022 width=\u0022549\u0022 height=\u0022413\u0022 alt=\u0022Low cycle fatigue tests on coupled bars for 10000 cycles under fully reversed stress range of \u00b1173 MPa\u0022 title=\u0022Low cycle fatigue tests on coupled bars for 10000 cycles under fully reversed stress range of \u00b1173 MPa\u0022 \/\u003E\u003C\/div\u003E\u003Cdiv class=\u0022field-item even\u0022\u003E\u003Cimg typeof=\u0022foaf:Image\u0022 src=\u0022https:\/\/serc.res.in\/sites\/default\/files\/halfen5.jpg\u0022 width=\u0022871\u0022 height=\u0022408\u0022 alt=\u0022Results of 16mm dia coupler bar after conducting 100 cycles test\u0022 title=\u0022Results of 16mm dia coupler bar after conducting 100 cycles test\u0022 \/\u003E\u003C\/div\u003E\u003Cdiv class=\u0022field-item odd\u0022\u003E\u003Cimg typeof=\u0022foaf:Image\u0022 src=\u0022https:\/\/serc.res.in\/sites\/default\/files\/halfen6.jpg\u0022 width=\u0022755\u0022 height=\u0022563\u0022 alt=\u0022Load deflection plot after conducting 100 cycle test\u0022 title=\u0022Load deflection plot after conducting 100 cycle test\u0022 \/\u003E\u003C\/div\u003E\u003C\/div\u003E\u003C\/div\u003E\u003Cdiv class=\u0022field field-name-field-project-enterprise-categor field-type-taxonomy-term-reference field-label-above clearfix\u0022\u003E\u003Ch3 class=\u0022field-label\u0022\u003EProject Enterprise Category: \u003C\/h3\u003E\u003Cul class=\u0022links\u0022\u003E\u003Cli class=\u0022taxonomy-term-reference-0\u0022\u003E\u003Ca href=\u0022\/ta\/research-expertise\/sustainable-materials-and-composites\u0022 typeof=\u0022skos:Concept\u0022 property=\u0022rdfs:label skos:prefLabel\u0022 datatype=\u0022\u0022\u003ESustainable Materials and Composites\u003C\/a\u003E\u003C\/li\u003E\u003C\/ul\u003E\u003C\/div\u003E  \u003C\/div\u003E\n\n      \u003Cdiv class=\u0022link-wrapper\u0022\u003E\n      \u003Cul class=\u0022links inline\u0022\u003E\u003Cli class=\u0022node-readless first\u0022\u003E\u003Ca href=\u0022\/ta\/more\/node\/2907\/teaser\u0022 class=\u0022use-ajax\u0022\u003ERead less\u003C\/a\u003E\u003C\/li\u003E\n\u003Cli class=\u0022translation_en\u0022\u003E\u003Ca href=\u0022\/studies-performance-evaluation-reinforcing-bar-couplers\u0022 title=\u0022Studies on performance evaluation of reinforcing bar couplers\u0022 class=\u0022translation-link\u0022 xml:lang=\u0022en\u0022\u003EEnglish\u003C\/a\u003E\u003C\/li\u003E\n\u003Cli class=\u0022translation_hi last\u0022\u003E\u003Ca href=\u0022\/hi\/studies-performance-evaluation-reinforcing-bar-couplers\u0022 title=\u0022Studies on performance evaluation of reinforcing bar couplers\u0022 class=\u0022translation-link\u0022 xml:lang=\u0022hi\u0022\u003E\u0939\u093f\u0928\u094d\u0926\u0940\u003C\/a\u003E\u003C\/li\u003E\n\u003C\/ul\u003E    \u003C\/div\u003E\n  \n  \n\u003C\/div\u003E","settings":null},{"command":"invoke","selector":"#node-2907","method":"addClass","arguments":["more-load node-teaser"]},{"command":"readmore_ajax","speed":"350"}]